High-piled combustible storage is defined as storage consisting of closely packed piles of combustible materials on pallets, in racks, or on shelves where the storage top is greater than 12 ft in height. When high-hazard commodities are involved (e.g., Group A plastics, rubber tires, flammable liquids, and idle pallets), minimum height drops to 6 ft. Most codes require that a high piled storage permit is obtained when more than 500 sq ft of high-piled storage is present in a building.
These permits are most often regulated by fire departments and are not transferable to new tenants or building owners. The reason for the prerequisite is that the required protection features are dependent on the proposed storage commodity, height, and method of storage, thus ensuring that each individual case be reviewed for compliance. Quite often, the existing protection (if present at all) is inadequate.
Potential clients frequently call in a panic, having purchased a building that was previously used as a warehouse or storage facility only to find out that they need to obtain a high-piled storage permit. Even when a facility is new and the project team is aware of the high-piled storage issue, those tasked with obtaining permits often are not fully aware of the requirements (including local ordinances) associated with this hazard or do not have a full understanding of the appropriate system design.
The required protection for high-piled storage areas falls into six main categorizes: automatic fire-extinguishing systems; fire detection system; building access; curtain boards, smoke and heat removal; small hose valves and stations; and storage limitations.
Automatic fire-extinguishing systems are typically provided using an automatic sprinkler system. Common installations include ESFR sprinklers, which are specifically designed for the protection of storage, or standard ceiling systems with in-rack sprinkler systems. The fire detection systems requirement usually includes smoke or heat detection, with a good requirement being beam-type smoke detection systems.
Building access involves providing the fire department with exterior access doors and an access road around the building. When curtain boards, and smoke and heat removal is required, automatic smoke and heat vents (operable skylights) are provided and the warehouse space is divided by curtain boards that extend 6 ft down from the ceiling into areas of 10,000 sq ft or less.
Small hose valves and stations, which are 1.25-in, hose valve connections and 100 ft of hose evenly spaced throughout the storage area, are typically required for manual fire fighting and mop-up operations by the fire department. Storage limitations represent a set of restrictions placed on aisle widths, size of storage piles, and flue spaces.
The most difficult protection issue in terms of design expertise is the sprinkler system. It tends to be the most cost intensive but also provides the most protection for the money. There have been numerous advances in recent years, with sprinkler companies continuing to produce a wider selection of products with different flow characteristics.
Pyrocop, Inc. has the expertise and code knowledge to help you design your racking system in accordance with all State and local codes. Your answers are only a phone call away!
Due to rising real estate costs and a shortage of storage space, “high-piled combustible storage” within buildings such as warehouses, manufacturing facilities, and retail buildings are growing upward in elevation to take up the least amount of square footage possible. As a result of ever changing building design there now is a need to increase fire protection and create new storage methods which present engineers with a variety of new challenges.
Fire Investigations
We offer you the choice of a comprehensive detailed report, or when appropriate, an outline of the services performed and a brief synopsis of our results.
Code Consulting
Our staff prides itself in its ability to work closely with code enforcing authorities to develop a relationship of trust and professional respect .
Expert Witness
When selecting a fire expert to represent you or your client's interests, knowledge, experience, and competence are of the utmost importance. With these qualities in mind, we also acknowledge that your particular case is unique and requires thorough review and professional, objective opinions.